Installation Instructions for standard basic systems

Open circuit circulation system

 

General

The AQUA HP-SYSTEM is integrated an existing circulations, like a cooling water circulation
or, if not existing
into a separate treatment circulation over an additional treatment tank.
For an optimal operation it is important that a constant water flow volume and a pressure of
approx. 6,0 to 8,0 bar is supplied to secure the correct function of the system unit.
The treated water is returned through the outlet pipe with a pressure of approx. 0,8 to 1,0 bar.
The free flow outlet of the treated water from the AQUA HP-SYSTEM must be maintained and
secured that no reduction of the nominal diameter of outlet the pipe is undertaken. Equally any
installation of filter units, contra valves or similar that may reduce the flow or pressure is to be
avoided, as such will backwards influence the reactor function. Only smooth pipe bending shall
be used and outlet pipe shall be above the water surface. Integration of the AQUA HP-SYSTEMS
into closed water circulation is an exception.
 
Materials to be applied

The pipes , valve and fittings
are locally and commercial available installation parts by
observing the required water pressure and pump capacity. The pump has to be
chosen according to the recommendation of the pump manufacturer.
On request the pump may
be a part of the AQUA HP-SYSTEM delivery.

AQUA HP-SYSTEME