FREQUENT ASKED QUESTIONS TO AQUA CORRECT Watertechnic (NR. 1)

WHAT IS THE MAJOR DIFFERENCE BETWEEN AQUA CORRECT WATER CONDITIONER AND OTHER MAGNETIC WATER TREATMENT PRODUCTS?

ANSWER: THE PRIMARY FUNCTION IS A REDUCTION OF THE WATER SURFACE TENSION.
AQUA CORRECT MAKE NO USE OF AGGRESSIVE CO
2 CREATED BY TURBULENCES.
AQUA CORRECT GUARANTEE AN UNRESTRICTED WATER FLOW!

View through the center of the Aqua Correct conditioner:

This is the unique difference: A total free, unrestricted flow.

The magnetic treatment is only effective, if certified a reduction of the water surface tension.
The value of the water surface tension reduction must be at least 4%-5%, but is only at 10% fully effective to dissolving all lime scale deposits (CaCO
3) in any water system. Turbulence has no influence on this reduction.

In most products you can remove the magnets and get exactly the same results as obtained with magnets.
An inside turbulence arrangement can occationally create aggressive free CO2, which may disolve lime scale (CaCO3).
This kind of treatment is not magnetic, but is fully dependent on the water quality, flow rate and turbulence construction.
Turbulence treatment is generally combined with inactive, low cost magnets for commercial reasons only.
The hidden turbulence arrangement is inserted in mostly all so-called "Magnetic" lime scale treatment products, however this is generally unknown to the customer. Some products are sealed in order to exclude the customer from dicovering the turbulence treatment arrangements.

Applications with a variable flow rate.
Although a number of product looks very similar to the Aqua Correct, the principle of operation and performance is very different.
About the turbulence treatment:
To create a turbulence that releases carbon dioxide, a defined flow rate through the unit is required. This means that if the flow rate changes, as normally in residential building, the results of the treatment change and becomes equally variable.
About the Aqua Correct treatment:
A real magnetic conditioning is independent of the flow rate and all the water passing through the conditioner is homogene treated - from the first drop.

How to discover if the treatment use turbulence, magnetic or a combination of both technical functions?
The significant difference between the two functions is that only magnets can physical reduce the water surface tension. In reality nearly all the implemented magnets in turbulence products do not accomplish this (ordinary low price magnets).

The conclusion:

If the manufacturer cannot provide a certified test confirming a reduced water surface tension and there is no free fluid flow, the function is a turbulence treatment only.
If a certified test is confirming a reduced water surface tension, but there is not a free fluid flow this indicates the combination of both turbulence and magnetic functions.
If the producer can provide a certified test confirming a reduced water surface tension and the product has an unrestricted, free inside flow, then the function is physically a pure magnetic treatment.