AQUA Hydro Physical Systems
Eliminate the life dangerous Legionella pneumophila bacteria
Elimination of Legionella and breeding biofilms in water supply systems
The AQUA Hydro Physical System is highly efficient for extermination of Legionella bacteria's in water supply systems.
Laboratory tests of the effect to kill dangerous Legionella bacteria's, present in a cold- and hot water supply systems to a clinical building in Berlin, was examined according to the German DVGB 552/BGA standard test procedure.
|
Test no.: Date: |
1. 16-02-2001 |
2 . 26-02-2001 |
3. 09-03-2001 |
4. 21-03-2001 |
5. 06-04-2001 |
|
Hot water supply |
127 CFU/ml |
36 CFU/ml |
244 CFU/ml Note 1) |
12 CFU/ml |
0-Detected |
|
Bad and Shower, 1. Section |
178 CFU/ml |
108 CFU/ml |
230 CFU/ml Note 1) |
14 CFU/ml |
0-Detected |
|
Swimming pool / Shower room |
- - |
- - |
- - |
3 CFU/ml |
0-Detected |
Concluded and certificated by the Microbiological Laboratories Dr. Th. Bernhard GmbH & Friend, Berlin, Germany
Test no. 1 colony forming units (CFU) level before installation of the AQUA Hydro Physical System.
Test no. 2 the significant reduction after only 10 days.
Test no. 3
Simultaneously with the installation of the AQUA Hydro Physical System, two AQUA Correct Conditioners for the removal of lime scale deposits were also installed on the water supply. Three weeks after this installation began the dissolving of substantial amount of existing lime scale in the pipelines, whereby imbedded biofilm with amoebae's and multiply infected by 10 thousands of Legionella pneumophila bacteria's was liberated into the water. This increased the CFU values significant and far above the first initial values in test no. 1.
Test no. 4 after 12 days, 95% of these legionella bacteria's was killed and in the following
Test no. 5 only 16 days later proved total eliminated, as the laboratory analysis states: "No detected (zero)".
To support the laboratory results after the impact of liberated biofilms in the existing lime scale deposits, the water from a third tapping place was included in the test (
Swimming pool / Shower room).Link to download of the original test reports (German language).
AQUA Hydro Physical Systems
Fabrication according to ISO 9001 - Materials: Stainless steel ASTM A 316Ti
Adopted by the AQUA Hydro Physical System: Natures unique biological degradable forces.
Links to AQUA CORRECT Water Conditioning for the prevention of lime scale deposits:
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_